Aerogel Thermal Insulation & Energy-Saving Coating is a white, smooth thermal insulation coating system for tanks, pipelines, roofs and high-temperature equipment where heat loss and condensation must be reduced.

Обзор продукта

Обзор продукта

Aerogel Thermal Insulation & Energy-Saving Coating is a white, smooth thermal insulation coating system for tanks, pipelines, roofs and high-temperature equipment where heat loss and condensation must be reduced.

Product System

Aerogel Thermal Insulation & Energy-Saving Coating

Aerogel Thermal Insulation & Energy-Saving Coating is a white, smooth thermal insulation coating system for tanks, pipelines, roofs and high-temperature equipment where heat loss and condensation must be reduced.

Core Advantages

01

White smooth finish

Creates a clean industrial surface that is easier to inspect than wrapped insulation in many exposed areas.

02

Thermal control

Helps reduce surface temperature, heat loss and condensation risk when applied at the designed thickness.

03

Complex-shape coverage

Sprayable or brushable coating reaches elbows, valves, tanks and irregular equipment surfaces.

Technical Parameters

Main substrateSteel tanks, pipelines, roofs, kiln shells and industrial equipment
FinishWhite matte or smooth thermal insulation film
Application methodLayer-by-layer spray, brush or trowel application
Acceptance focusThickness, surface temperature target, adhesion and weather exposure condition
Certification SupportCE / RoHS / ASTM / EN documentation support
Construction ControlConfirm substrate preparation, primer compatibility, wet film thickness and curing condition before batch application.

Application Scenes

Application Scenes

Aerogel thermal insulation coating for building roof, exterior wall and industrial pipeline energy-saving project photo
Tank and pipeline insulationCoating insulation for exposed tanks, pipelines and process equipment.
Aerogel thermal insulation coating for building roof, exterior wall and industrial pipeline energy-saving project photo
Roof energy savingReflective and insulation support for industrial roofs and building envelopes.

REFERENCE TDS DATA

Aerogel Insulation Coating Reference Data

Key data below is extracted from the June 2026 aerogel coating technical document for insulation, heat preservation and anticorrosion use.

Aerogel thermal insulation coating product detail real photoAerogel insulation coating applied on industrial thermal insulation scene real photo

Core Features

01

Waterborne ceramic-fiber emulsion

White thick waterborne ceramic fiber emulsion coating for thermal insulation, heat preservation and corrosion protection.

02

Low thermal conductivity

The document lists thermal conductivity <=0.032 W/(m.K), density 80-150 g/L and bond strength >=0.7 MPa.

03

Fire-retardant and RoHS compliant

The reference data lists UL94 V-0 flame-retardant level and RoHS harmful-substance compliance.

Technical Parameters

Color / formWhite, thick waterborne ceramic fiber emulsion
Packaging5 L / 12 L / 25 L
Usage1 kg can spray about 2 m2 and reach about 1 mm thickness; one-pass application can form the coating, while high-temperature conditions are recommended to use 2 passes
Drying time4-12 h depending on temperature and humidity
ResistanceWater resistance 96 h; alkali resistance 48 h
Shelf life36 months in sealed dry storage

Application Fields

Concrete, putty wall, emulsion-painted wall, glass, metal, steel structure, pipeline, storage tank, roof, balcony, underground room and other building or industrial surfaces.

Product Advantages

Provides coating-type insulation for complex surfaces where wrapped insulation is difficult, helping reduce heat transfer, condensation risk and surface temperature while keeping a maintainable coating finish.

Construction Instructions

  1. The substrate must be dry, flat, solid and clean, without loose dust, powdering or oil contamination.
  2. Roller, brush, trowel or spray can be used. One-pass application can form the coating; for high-temperature conditions, 2 passes are recommended.
  3. If viscosity is too high, dilute with clean water but keep added water within 10% of coating weight. Maintain natural ventilation after application.

Технические параметры

Технические параметры

Область применения
Кровли заводов, резервуары, трубопроводы, стены и поверхности оборудования
Уровень характеристик
По цели изоляции и температуре поверхности
Подходящее основание
Металл, бетон, кровельные панели, резервуары и трубы
Рекомендуемая система
Антикоррозионный или герметизирующий грунт + аэрогельный слой + защитное покрытие
Особенности продукта
Низкая теплопроводность, тонкий слой, энергосбережение и водная формула
Сертификаты
Проектная цена
Расчет по площади, толщине, упаковке и порту назначения
Поддержка образцов
Платные образцы и технический пакет доступны
Настройка упаковки
OEM/ODM цвет, этикетка, упаковка и экспортные документы

Инструкция по нанесению

Инструкция по нанесению

01

Подходящее основание: Металл, бетон, кровельные панели, резервуары и трубы

02

Рекомендуемая система: Антикоррозионный или герметизирующий грунт + аэрогельный слой + защитное покрытие

03

Особенности продукта: Низкая теплопроводность, тонкий слой, энергосбережение и водная формула

Связанные технические статьи

Связанные технические статьи

Связанные продукты

Связанные продукты

Chat Now
Get Free QuoteReply within 12 hours